S-CAPE II Set-up and trouble shooting.
Before beginning,
make sure bed is plugged into a working, grounded outlet. You can test
the outlet by plugging in a lamp or radio.
1-Check to see if
the Transmission Indicator illuminates, you can do this by pressing any
button on the remote.
*If not, check to see if the batteries are installed
correctly. Replace the batteries if needed.
*If yes, try performing the Auto Learn Function
outlined below:
Press and
hold the POS 1 and HEAD MASSAGE ON/OFF buttons (See diagram below). The
transmission light will flash slowly and then flash rapidly. Continue to
hold for 10 seconds and then release the buttons. Note: If
using the Auto Learn Function when more than one wireless equipped bed is
in transmission range (approx. 50’ radius), you must remove power
from all beds not intended to learn the code.
2-If the bed still
does not operate after performing the Auto Learn Function, turn the bed
over or on its side and follow the procedures outlined below:
*Be sure the
power down box is plugged in to the correct port. The POWER DOWN plug
should be in the POWER DOWN connector port (the wires are red and black
and are labeled, the connector port is also labeled). The RF/IR INPUT
plug should be in the RF/IR INPUT connector port (the wires are blue,
green, and yellow, and are labeled, the connector port is also labeled).
*Check to be
sure the dip switched are set correctly. YOU MUST UNPLUG THE BED
BEFORE ATTEMPTING TO CHANGE THE DIP SWITCH SETTINGS. They MUST be in
following order:
1-Down,
2-UP, 3-DOWN, 4-UP, 5-UP, 6-UP, 7-UP, 8-DOWN,
Adjust the
switches as necessary.
*Be sure the
ABC Switch on the motor is set to “C”
Plug bed back into
outlet. Reprogram the hand control.
If bed still does not
operate, please call Warranty Department: Eastern and Central Time Zones
1-800-888-3078 Mountain, Pacific, and Hawaii Time Zones and Canada
1-800-345-4333
NOTE: The Headboard
Brackets and the Mattress Retainer Brackets are located on the underside
of the base unit.
Place headboard
bracket assembly onto frame of bed as shown in Detail A. Loosely
attach headboard bracket assembly to the frame, using the 4 bolts
provided. Slide the assembly into position leaving a 1 ½” space between
the edge of the bed and the face of the headboard bracket. Tighten
bolts. Repeat procedure to attach other headboard bracket.
Measure the distance
between headboard bracket slots as shown in Detail B and measure
the distance between holes in the headboard. Remove bolts indicated in
Detail B to make width adjustment. After width adjustment is made,
reinstall bolts and tighten securely.
MATTRESS RETAINER
BRACKET
Place washers and
spacers on the four screws as detailed in the adjacent diagram. Loosely
install each of the four screws into the pre-punched
holes at the foot of
the bed. Slide the mattress retainer between the trim washer and the
standard washer as shown in the adjacent diagram. Tighten screws. The
mattress retainer must be used or the mattress will slide off the end of
the bed when the head is raised. Unpack the mattress and place it on
the base unit. Dispose of all plastic packing material.